  4 145 algonquin parkway, whippany, nj 07981 ?973-560-0019 ?fax: 973-560-0076 e-mail: filtersales@powerdynamics.com www.powerdynamics.com specifications subject to change without notice. dimensions (mm). see appendix a for recommended power cord. see pdi full line catalog for detailed specifications on power cords. right angle, flange mount filter with iec 60320 ac inlet socket. pa series mechanical dimensions features general purpose, low cost filter with iec connector providing effective equipment protection of line-to-ground noise up to 15 amp, 250vac. the compact design filter with low leakage current is well suited for applications that require strict emission standards. these filters are also available for medical application and offer extremely low leakage current to comply with various industry standards. ground choke can be added to enhance the grounding ability of the circuit. bleeder resistor can be added to prevent excessive voltages from developing across the filter capacitors when there is no load. applications computer & networking equipment, measuring & control equipment, data processing equipment, laboratory instruments, switching power supplies, other electronic equipment. technical data rated voltage: 115/250vac rated current: 1a, 2a, 3a, 6a, 10a, 15a power line frequency: 50/60hz max. leakage current each line to ground: @ 115vac 60hz: 0.25ma @ 250vac 50hz: 0.45ma @ 115vac 60hz: 2 a* @ 250vac 50hz: 5 a* hipot rating (one minute) line to ground: 2250vdc line to line: 1450vdc temperature range: -25c to +85c (unit: mm) * medical application  50.1 30.3 22.5 g g 40.0 2x 3.3 13.9 32.8 20.2 24.4 36.3 39.8 40.0 30.5 2x 3.5 4x r4.5 suggested panel cutout (mounting from front) 21.8 41.3 28.4
5 145 algonquin parkway, whippany, nj 07981 ?973-560-0019 ?fax: 973-560-0076 e-mail: filtersales@powerdynamics.com www.powerdynamics.com current rating (a): = 01 = 02 = 03 = 06 = 10 = 15* terminal: = q = s = w options: = 00 = 50 = 60 = 70 = 80 = 90 quick connect solder wire no bleeder resistor & ground choke bleeder resistor (1/4 w, 1m) bleeder resistor (1/2 w, 1m) bleeder resistor (1/4 w, 1m) & ground choke bleeder resistor (1/2 w, 1m) & ground choke ground choke (100 h) component locations: = 1 = 2 ? = 3 ? = 4 ? = 1m = 2m ? standard type without c(x); c(y) only c(x) & c(y) behind l without c(x) & c(y) without c(y); c(x) only without c(y); c(x) behind l pa series example & ordering code 6.3/0.25 4.0/0.187 ul 1015, 18awg stranded, 4 schematics medical schematics attenuation code table: cx inductance per current rating (mh) (f) 1a 2a 3a 6a 10a 15a 0.1 6.5 3.8 2.5 0.8 0.2 0.18 0.015 1.9 1.5 1.1 0.6 0.3 0.18 0.1 3.7 2.7 1.8 0.8 0.3 0.18 0.1 10.5 4.2 2.5 1.05 0.3 0.18 0.047 4.6 3.4 2.5 0.9 0.3 0.18 0.033 9.5 4.3 1.8 0.85 0.3 0.18 0.047 10.5 4 1.2 0.53 0.3 0.18 0.033 5 3.7 1.8 0.6 0.2 0.18 medical applications, select attenuation code with corresponding component values from the table. non-medical applications, select attenuation code with corresponding component values from the table. cx cy inductance per current rating (mh) (f) (pf) 1a 2a 3a 6a 10a 15a 0.1 2200 6.5 3.8 2.5 0.8 0.2 0.18 0.015 3300 1.9 1.5 1.1 0.6 0.3 0.18 0.1 3300 3.7 2.7 1.8 0.8 0.3 0.18 0.1 1000 10.5 4.2 2.5 1.05 0.3 0.18 0.047 3300 4.6 3.4 2.5 0.9 0.3 0.18 0.033 3300 9.5 4.3 1.8 0.85 0.3 0.18 0.047 2200 10.5 4 1.2 0.53 0.3 0.18 0.033 2200 5 3.7 1.8 0.6 0.2 0.18 without cx without cy 10.5 6.5 2.5 1.05 0.3 0.18 = a = b = c = d = e = f = g = h = i c x g line load l mh l mh cy l n l l' n' g' lg cy r 1 2 g line load l mh l mh cy l n l l' n' g' lg cy r 3 g line load l mh l mh l n l l' n' g' lg r cy cy c x 1m g' c x g line load l mh l mh l n l l' n' lg r 2m g' g line load l mh l mh l n l l' n' lg r c x 10.0 2.0 -3.6l .8mm b 8.0 2.0 m = m1 = m2 = m3 = m4 = m5 = m6 = m7 = m8 g' g line load l mh l mh l n l l' n' lg r 4 ? contact pdi for attenuation numbers *15a for ul, csa; 10a for ce, vde pa - - 01 q 50 1 c
6 145 algonquin parkway, whippany, nj 07981 ?973-560-0019 ?fax: 973-560-0076 e-mail: filtersales@powerdynamics.com www.powerdynamics.com medical applications non-medical applications pa series attenuation tables comm. mode(l-g) in mhz diff. mode(l-l) in mhz .15 .5 1 5 10 30 .15 .5 1 5 10 30 34 38 39 32 16 21 9 26 37 62 51 11 29 32 34 30 19 16 8 23 34 60 48 13 28 35 37 28 22 19 8 19 28 52 44 12 18 22 24 27 25 18 8 18 26 52 45 27 8 13 15 17 16 14 8 18 25 32 28 24 7 12 15 16 14 11 7 17 24 41 32 23 25 31 33 30 24 21 1 5 14 41 46 17 23 27 28 29 24 23 1 5 14 45 58 15 19 22 24 27 27 20 1 4 10 39 50 34 15 21 24 23 21 17 1 4 9 30 49 28 11 16 18 17 16 12 1 4 8 26 45 24 7 13 15 16 14 11 1 3 7 26 39 23 29 33 34 30 20 16 8 24 35 58 45 15 28 35 37 28 22 24 8 20 29 61 48 15 25 33 58 51 56 41 8 20 30 57 47 13 19 26 29 28 25 14 8 18 26 46 43 22 11 16 18 18 16 12 8 18 24 47 36 24 36 41 43 37 32 28 8 23 34 60 53 30 31 37 39 35 29 22 8 22 32 66 55 22 28 35 37 28 21 21 8 20 29 54 44 14 22 28 31 30 27 16 8 18 26 43 43 26 12 16 18 20 19 15 8 18 24 49 42 27 32 37 40 35 29 23 3 15 25 74 58 21 29 33 34 30 16 21 3 16 27 57 50 20 28 35 37 28 22 23 3 13 22 59 48 16 18 23 25 27 26 20 3 12 19 48 49 30 11 16 18 18 17 14 3 11 17 42 38 27 7 13 15 16 14 11 3 11 17 43 30 22 36 41 43 37 31 25 1 12 23 54 57 28 32 37 40 36 30 22 1 11 22 63 59 24 23 27 28 31 30 30 1 10 19 61 52 32 19 26 29 29 25 17 1 8 15 39 45 25 11 16 18 18 17 14 2 8 14 42 34 25 41315161411 1 814482921 36 41 43 37 32 28 3 16 27 64 60 31 31 37 40 36 29 25 3 15 25 80 60 25 20 24 25 26 24 23 3 12 21 47 42 22 14 17 19 22 22 19 3 11 18 43 35 29 11 16 18 18 16 12 3 11 17 48 34 23 32 36 37 28 19 11 1 14 26 53 42 16 29 33 34 31 20 17 1 13 24 61 50 14 23 26 28 31 30 31 1 9 19 54 53 29 16 19 21 24 24 21 2 8 15 56 38 33 11 16 18 18 17 14 2 8 14 41 34 25 comm. mode(l-g) in mhz diff. mode(l-l) in mhz .15 .5 1 5 10 30 .15 .5 1 5 10 30 34 38 40 32 26 11 8 25 37 71 62 12 29 32 55 48 49 51 8 23 34 68 64 14 28 36 39 45 48 39 8 19 27 58 65 15 18 24 28 44 50 47 8 18 26 43 51 31 8 14 18 33 41 39 8 18 25 29 38 31 7 14 19 34 40 38 7 17 23 39 47 27 25 31 33 30 25 14 1 4 12 50 64 16 24 28 20 53 54 55 1 4 13 53 57 16 19 22 24 27 27 22 1 3 8 48 59 31 15 24 30 44 52 40 1 4 8 36 52 28 11 18 23 39 49 37 1 4 8 26 46 24 7 15 20 38 46 37 1 4 8 25 48 28 29 33 47 53 57 41 8 23 35 73 58 14 28 37 44 52 56 41 8 19 27 74 59 17 25 33 46 53 57 44 8 19 29 63 62 13 19 29 36 49 55 46 8 18 23 50 54 24 11 19 24 41 53 36 8 18 24 51 46 25 7 15 21 37 46 36 7 17 23 39 48 27 36 41 41 49 49 46 8 23 33 62 62 32 36 41 41 49 49 46 8 23 33 62 62 32 28 35 37 41 42 42 8 19 28 56 57 17 21 28 31 41 44 41 8 18 25 45 48 29 12 16 19 45 37 41 8 18 24 52 53 30 7 13 16 28 32 37 7 17 24 32 32 30 32 39 55 55 56 52 3 14 25 75 63 24 29 34 46 56 58 49 3 15 27 67 59 21 28 38 44 51 58 39 3 12 20 66 57 18 18 25 31 49 56 47 3 11 17 55 59 32 11 19 24 40 50 40 3 12 17 48 46 29 7 14 20 39 45 37 3 11 17 50 46 29 36 41 62 54 50 36 1 11 22 64 70 29 32 39 56 56 58 58 1 10 21 76 62 23 23 29 35 53 52 40 1 9 17 66 65 33 19 29 35 51 54 49 2 8 13 47 57 28 11 19 25 40 51 39 2 9 14 46 51 29 41521364438 1 8 14504626 36 41 59 54 54 47 3 15 26 68 71 32 31 37 47 51 49 40 3 14 24 69 63 26 20 25 28 44 49 42 3 12 19 61 57 27 14 19 22 39 48 41 3 11 17 48 50 33 11 17 22 36 42 38 3 11 17 39 55 27 4 14 19 34 40 38 3 12 17 38 42 28 32 34 52 44 44 41 1 14 25 60 66 21 29 32 56 49 50 45 1 12 24 67 62 14 23 27 30 49 52 46 1 9 17 59 69 30 16 20 24 42 51 42 1 8 14 58 52 33 11 17 22 36 41 40 2 8 14 37 54 27 41419333939 1 8 14484228 36 42 43 37 31 36 1 2 5 17 23 33 30 37 39 29 22 27 1 1 3 14 21 13 28 35 37 28 22 31 1 1 2 11 18 12 21 29 32 31 27 17 1 1 1 7 12 23 11 16 18 18 17 14 1 1 1 s 3 9 61215161511 1 1 1 1 3 6 attenuation code a b c d e f g h i attenuation code m1 m2 m3 m4 m5 m6 m7 m8 current rating 1a 2a 3a 6a 10a 15a 1a 2a 3a 6a 10a 15a 1a 2a 3a 6a 10a 1a 2a 3a 6a 10a 1a 2a 3a 6a 10a 15a 1a 2a 3a 6a 10a 15a 1a 2a 3a 6a 10a 1a 2a 3a 6a 10a ? this table applies to schematic 1m only. visit our website or contact pdi for other schematic attenuation numbers. ? this table applies to schematic 1 only. visit our website or contact pdi for other schematic attenuation numbers. ? ? insertion loss in db (50 ohm circuit) insertion loss in db (50 ohm circuit) current rating 1a 2a 3a 6a 10a 15a 1a 2a 3a 6a 10a 15a 1a 2a 3a 6a 10a 15a 1a 2a 3a 6a 10a 15a 1a 2a 3a 6a 10a 15a 1a 2a 3a 6a 10a 15a 1a 2a 3a 6a 10a 15a 1a 2a 3a 6a 10a 15a 1a 2a 3a 6a 10a 15a


▲Up To Search▲   

 
Price & Availability of PA01Q-90-1A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X